CARRIER FB4CNF INSTALLATION INSTRUCTIONS MANUAL Pdf Download (2024)

FB4CNF, FB4CNP, FX4D

FAN COIL UNITS

SIZES 018 TO 060

NOTE: Read the entire instruction manual before starting the installation.

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance, or

use can cause explosion, fire, electrical shock, or other conditions which

may cause death, personal injury or property damage. Consult a

qualified installer, service agency, or your distributor or branch for

information or assistance. The qualified installer or agency must use

factory-authorized kits or accessories when modifying this product.

Refer to the individual instructions packaged with kits or accessories

when installing.

Follow all safety codes. Wear safety glasses, protective clothing and

work gloves. Have a fire extinguisher available. Read these instructions

thoroughly and follow all warnings or cautions included in literature and

attached to the unit. Consult local building codes and the current editions

of the National Electrical Code (NEC) NFPA 70.

In Canada, refer to the current editions of the Canadian Electrical Code

CSA C22.1.

Recognize safety information. This is the safety-alert symbol

you see this symbol on the unit and in instruction manuals, be alert to the

potential for personal injury.

Understand the signal words DANGER, WARNING, and CAUTION.

These words are used with the safety-alert symbol. DANGER identifies

the most serious hazards which will result in severe personal injury or

death. WARNING signifies hazards which could result in personal

injury or death. CAUTION is used to identify unsafe practices which

may result in minor personal injury or product and property damage.

NOTE is used to highlight suggestions which will result in enhanced

installation, reliability, or operation.

WARNING

!

ELECTRICAL OPERATION HAZARD

Failure to maintain proper clearances could result in personal injury or

death.

Before installing or servicing unit, always turn off all power to unit.

There may be more than 1 disconnect switch. Turn off accessory heater

power if applicable.

CAUTION

!

CUT HAZARD

Failure to follow this caution may result in personal injury.

Sheet metal parts may have sharp edges or burrs. Use care and wear

appropriate protective clothing, safety glasses and gloves when

handling parts.

INTRODUCTION

FB4C and FX4D models are R-410A Fan Coils designed for installation

flexibility. These units leave the factory compliant with low leak

requirements of less than 2% cabinet leakage rate at 0.5 inches W.C. and

Installation Instructions

. When

1.4% cabinet leakage rate at 0.5 inches W.C. when tested in accordance

with ASHRAE 193 standard.

FB4CNF(018-048) uses a refrigerant piston metering device. A TXV is

used on FB4CNP and FX4D(018-061). All these fan coils use a

multi-tap ECM motor for efficiency. The units have be designed for

upflow, downflow (kit required), and horizontal orientations, including

manufactured and mobile home applications.

These units require a field supplied air filter, and are designed

specifically for R-410A refrigerant air conditioners and heat pumps as

shipped. These units are available for systems of 18,000 through 60,000

BTUh nominal cooling capacity. Factory- authorized, field - installed

electric heater packages are available in sizes 5 through 30kW. See

Product Data literature for all available accessory kits.

HEATER PACKAGES

This unit may or may not be equipped with an electric heater package.

For units not equipped with factory-installed heat, a factory-approved,

field-installed, UL listed heater package is available from your

equipment supplier. See unit rating plate for a list of factory-approved

heaters. Heaters that are not factory approved could cause damage which

would not be covered under the equipment warranty. If fan coil contains

a factory-installed heater package, minimum circuit ampacity (MCA)

and maximum fuse/breaker may be different than units with a same size

field-installed accessory heater. The differences is not an error and is due

to calculation difference per UL guidelines.

INSTALLATION

CHECK EQUIPMENT

Unpack unit and move to final location. Remove carton taking care not

to damage unit.

NOTE: If the door gasket is damaged or missing, the unit may not meet

the ASHRAE 193 standard for cabinet air leakage. Contact your supplier

and order kit #344994-751.

Inspect equipment for damage prior to installation. File claim with

shipping company if shipment is damaged or incomplete. Locate unit

rating plate which contains proper installation information. Check rating

plate to be sure unit matches job specifications.

MOUNT UNIT

Unit can stand or lie on floor, or hang from ceiling or wall. Allow space

for wiring, piping, and servicing unit.

IMPORTANT: When unit is installed over a finished ceiling and/or

living area, building codes may require a field-supplied secondary

condensate pan to be installed under the entire unit. Some localities may

allow as an alternative, the running of a separate, secondary condensate

line. Consult local codes for additional restrictions or precautions.

NOTE: Nuisance sweating may occur if the unit is installed in a high

humidity environment with low airflow.

UPFLOW INSTALLATION

If return air is to be ducted through a floor, set unit on floor over opening

and use 1/8 to 1/4-in (3 to 6 mm) thick fireproof resilient gasket between

duct, unit, and floor.

Side return is a field option on slope coil models. Cut opening per

dimensions. (See Fig. 1.) A field-supplied bottom closure is required.

CARRIER FB4CNF INSTALLATION INSTRUCTIONS MANUAL Pdf Download (2024)

References

Top Articles
Latest Posts
Article information

Author: Msgr. Benton Quitzon

Last Updated:

Views: 5751

Rating: 4.2 / 5 (63 voted)

Reviews: 86% of readers found this page helpful

Author information